Extrarenal plasma clearance of iohexol, chromium-51-ethylenediaminetetraacetic acid, and inulin in anephric pigs

Författare

  • Bo Frennby
  • Gunnar Sterner
  • Torsten Almén
  • Chun-Ming Chai
  • Bo-Anders Jönsson
  • Sven Månsson

Summary, in English

RATIONALE AND OBJECTIVES: To improve the measurement of the glomerular filtration rate (GFR), we determined the extrarenal plasma clearance of the GFR markers iohexol, chromium-51-ethylenediaminetetraacetic acid (51Cr-EDTA), and inulin using 11 anephric pigs. METHODS: After an intravenous (i.v.) bolus injection of the markers, the decay curves of their plasma concentrations were monitored for 29 hr by 16 plasma samples. The area under the curve (AUC; concentration of marker versus time) was calculated according to one- and three-compartment kinetics. The extrarenal clearance was calculated by dividing the dose of marker by the AUC. RESULTS: In the three-compartment model, the median of the extrarenal clearances of iohexol, 51Cr-EDTA, and inulin were 0.87 ml.min-1.10 kg-1 (range = 0.62-1.26 ml.min-1.10 kg-1), 0.79 ml.min-1.10 kg-1 (range = 0.61-1.04 ml.min-1.10 kg-1), and 0.83 ml.min-1.10 kg-1 (range = 0.65-1.17 ml.min-1.10 kg-1). The extrarenal clearance of 51Cr-EDTA was slightly lower than that of iohexol and inulin when measured with the three-compartment model (p = .015). There was no statistically significant difference between the two models of kinetics in calculating clearance of the same marker. CONCLUSION: Our results indicate that subtracting the median values of the extrarenal clearance of the markers from the total plasma clearance will provide GFR values closer to the "true" GFR. This technique might prove useful in GFR calculations in patients with a very low GFR (e.g., residual GFR in patients on dialysis)

Avdelning/ar

  • Diagnostisk radiologi, Malmö
  • Institutionen för kliniska vetenskaper, Malmö
  • Medicinsk strålningsfysik, Lund

Publiceringsår

1996

Språk

Engelska

Sidor

145-153

Publikation/Tidskrift/Serie

Academic Radiology

Volym

3

Issue

2

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Radiology, Nuclear Medicine and Medical Imaging

Nyckelord

  • Extrarenal clearance
  • iohexol
  • chromium-51-ethylenediaminetetraacetic acid
  • glomerular filtration rate
  • inulin

Status

Published

Forskningsgrupp

  • Radiology Diagnostics, Malmö

ISBN/ISSN/Övrigt

  • ISSN: 1878-4046