X-ray Phase-contrast imaging

Martin Bech

Universitetslektor

X-ray Phase-contrast imaging

Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

Författare

  • Astrid Velroyen
  • Martin Bech
  • Arne Tapfer
  • Andre Yaroshenko
  • Mark Müller
  • Philipp Paprottka
  • Michael Ingrisch
  • Clemens C Cyran
  • Sigrid D Auweter
  • Konstantin Nikolaou
  • Maximilian F Reiser
  • Franz Pfeiffer

Summary, in English

The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.

Avdelning/ar

  • Medicinsk strålningsfysik, Lund

Publiceringsår

2015

Språk

Engelska

Publikation/Tidskrift/Serie

PLoS ONE

Volym

10

Issue

7

Dokumenttyp

Artikel i tidskrift

Förlag

Public Library of Science (PLoS)

Ämne

  • Radiology, Nuclear Medicine and Medical Imaging

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1932-6203