Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Default user image.

Ronnie Wirestam

Professor

Default user image.

Toward Super-Resolution Reconstruction of Diffusion–Relaxation MRI Using Slice Excitation With Random Overlap (SERO)

Författare

  • Felix Mortensen
  • Jakub Jurek
  • Jens Sjölund
  • Geraline Vis
  • Ronnie Wirestam
  • Malwina Molendowska
  • Andrzej Materka
  • Filip Szczepankiewicz

Summary, in English

Purpose: Diffusion MRI probes tissue microstructure, but low SNR and limited resolution hinder detection of features and parameter estimates. We introduce slice excitation with random overlap (SERO), which enables variable repetition times (TRs) and diffusion weighting within a single shot. This acquisition supports super-resolution reconstruction of baseline signal ((Formula presented.)), diffusivity ((Formula presented.)), diffusional variance ((Formula presented.)), and longitudinal relaxation ((Formula presented.)) maps. Methods: We implemented a diffusion-weighted spin-echo sequence in Pulseq that excites thick slices at random positions. Across shots, pseudo-random overlap produces inter- and intra-slice TR variation (0.15–21.9 s) with b-values up to 1.4 ms/μm2. The (Formula presented.) -weighting enables through-slice super-resolution and allows (Formula presented.) estimation. Accuracy and precision were evaluated in numerical phantoms across variable SNR. SERO was compared with slice-shifting super-resolution and conventional high-resolution imaging. Feasibility was demonstrated in healthy brain in vivo at 1.5-mm isotropic resolution in 2:30 min. Results: In simulations SERO improved accuracy of (Formula presented.), (Formula presented.), and (Formula presented.) while maintaining voxel-wise precision comparable to direct sampling across SNRs. Regularized SERO achieved RMSE ≈ 0.5 μm2/ms ((Formula presented.)) and ≈ 0.5 μm4/ms2 ((Formula presented.)) at SNR = 3, whereas direct sampling required SNR ≥ 7–10; root-mean–variance decreased by > 50% versus an unregularized fit. In vivo, SERO yielded sharp tissue boundaries and smooth parameter maps. Conclusion: Random slice overlap enriches encoding diversity, improving accuracy and precision of diffusion and relaxation parameters without longer scan time. SERO offers a novel path to high-resolution microstructural imaging, especially at low SNR.

Avdelning/ar

  • Medicinsk strålningsfysik, Lund
  • MR Physics
  • Diagnostisk radiologi, Lund
  • LTH profilområde: Teknik för hälsa
  • LUCC: Lunds universitets cancercentrum
  • Multidimensional microstructure imaging
  • eSSENCE: The e-Science Collaboration

Publiceringsår

2026

Språk

Engelska

Sidor

3213-3226

Publikation/Tidskrift/Serie

Magnetic Resonance in Medicine

Volym

95

Avvikelse

6

Dokumenttyp

Artikel i vetenskaplig tidskrift

Förlag

John Wiley & Sons Inc.

Ämne

  • Radiology and Medical Imaging

Nyckelord

  • diffusion MRI
  • diffusion–relaxation imaging
  • diffusion–weighted imaging
  • pulse sequence design
  • super-resolution reconstruction
  • T mapping

Aktiv

Published

Forskningsgrupp

  • MR Physics
  • Multidimensional microstructure imaging

ISBN/ISSN/Övrigt

  • ISSN: 0740-3194