Registration of emission and transmission whole-body scintillation-camera images

Författare

  • Katarina Sjögreen Gleisner
  • Michael Ljungberg
  • Karin Wingårdh
  • Kjell Erlandsson
  • Sven-Erik Strand

Summary, in English

In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. METHODS: Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an (131)I-labeled monoclonal antibody and for Monte Carlo-simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. RESULTS: For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 10(5) (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 +/- 5 mm. CONCLUSION: An automatic registration method for WB images has been developed, which is applicable to emission-emission and transmission-emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.

Avdelning/ar

  • Medicinsk strålningsfysik, Lund

Publiceringsår

2001

Språk

Engelska

Sidor

1563-1570

Publikation/Tidskrift/Serie

Journal of Nuclear Medicine

Volym

42

Issue

10

Dokumenttyp

Artikel i tidskrift

Förlag

Society of Nuclear Medicine

Ämne

  • Radiology, Nuclear Medicine and Medical Imaging

Nyckelord

  • whole-body image registration
  • conjugate view
  • planar activity quantification
  • mutual information